OEM Factory for Incubator Normal Temperature - DRK-6000 Series Vacuum drying oven – Drick

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We thinks what clients think, the urgency of urgency to act from the interests of a purchaser position of principle, allowing for greater top quality, decrease processing costs, price ranges are much more reasonable, won the new and aged prospects the support and affirmation for Pesticide Residue Analysis Equipment, Pesticide Residue Test, Types Of Pesticide Residue Test, We welcome you to definitely stop by our manufacturing facility and sit up for creating pleasant organization relationships with clients in your own home and overseas while in the in the vicinity of long term.
OEM Factory for Incubator Normal Temperature - DRK-6000 Series Vacuum drying oven – Drick Detail:

1.Fahrenheit/Celsius free conversion to meet different customer needs.

2.Hyperbolic temperature calibration system, more accurate temperature measurement.

3.Standard large-screen LCD color screen, multiple sets of data displayed on one screen,menu-style operation interface, easy to understand and easy to operate.

4.It adopts a controller with over-temperature deviation protection and a microcomputer PID fuzzy processing controller to quickly reach the preset temperature and run stably.

5.304 mirror stainless steel liner, semi-circular design at four corners, easy to clean.

6.The sealing design of the new synthetic silicon sealing strip effectively prevents heat loss, and can extend the service life of each component on the basis of energy saving by 30%.

7.The aluminum separator stamped by a special process has high temperature non-oxidation and fast heat conduction. Minimize heat loss.

8.The double-layer bulletproof glass observation window allows you to observe the objects in the working room at a glance.

9.The tightness of the box door is completely adjusted by the user at will. The integrally formed silicone rubber door seal ring ensures the high vacuum in the box.

10.Imported vacuum valve avoids the drop problem caused by long-term use of traditional vacuum valve.

1.Independent limit temperature alarm system-when the limit temperature is exceeded, the heating source is forced to stop, escorting your laboratory safety.

2.RS485 interface and special software-connect to a computer, export experimental data.

3.Intelligent program controller-30-step programming process can be set to meet various complex experiments.

Project

6020

6050

6090

6210

6500

Power

AC220V  50HZ

Temperature control range

RT+10~250℃

Constant temperature fluctuation

±1℃

Temperature resolution

0.1℃

Vacuum

≤133Pa

Input power

450W

 650W

1200W

2000W

3000W

Liner size

W×D×H(mm)

300×300×275

415×370×345

450×450×450

560×600×640

630×510×845

Dimensions

W×D×H(mm)

615×470×470

830×640×540

615×660×1440

720×805×1680

790×1030×1855

Nominal volume

20L

50L

90L

210L

500L

Carrying bracket (standard

External heating, 1 screen

Extractable

External heating, 2 screen

Extractable

Internal heating, 2 fast partitions cannot be extracted

Internal heating,3 fast partitions cannot be extracted

Internal heating, 4 fast partitions cannot be extracted

Liner material

304 stainless steel

Timing range

1~9999min

Note:The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.

When the input power is ≥2000W, a 16A plug is configured, and the rest of the products are configured with a 10A plug.

Except 6090 and 6210 series equipped with vacuum pumps, all other models are equipped with vacuum pumps.


Product detail pictures:

OEM Factory for Incubator Normal Temperature - DRK-6000 Series Vacuum drying oven – Drick detail pictures


Related Product Guide:

Excellent 1st,and Client Supreme is our guideline to deliver the ideal provider to our prospects.Nowadays, we have been seeking our best to become certainly one of the most effective exporters in our discipline to meet shoppers more require for OEM Factory for Incubator Normal Temperature - DRK-6000 Series Vacuum drying oven – Drick , The product will supply to all over the world, such as: Lithuania, South Korea, Czech republic, Since the establishment of our company, we've realized the importance of providing good quality goods and the best before-sales and after-sales services. Most problems between global suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question points they do not understand. We break down these barriers to ensure you get what you want to the level you expect, when you want it.
  • Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Bertha from Ethiopia - 2018.06.28 19:27
    This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By Sabina from Denmark - 2017.10.23 10:29
    Write your message here and send it to us